Common Symptoms
- Inverter displays “No Battery Communication”, “CAN Error”, or “BMS offline”
- SOC stuck at 0% or 100%
- Charge/discharge disabled
- Incorrect battery voltage or capacity reading
- Inverter switches to “lead-acid fallback mode”
Root Causes
- Incorrect communication protocol selection (Pylontech, BYD, or vendor-specific).
- Wrong baud rate or CAN-ID mismatch.
- Incorrect wiring or loose communication cable.
- Damaged CAN/RS485 port from ESD or miswiring.
- Firmware version mismatch between inverter and battery BMS.
- Multiple battery packs not properly addressed or terminated in parallel connection.
Diagnostic Checklist
- Confirm protocol selection in inverter’s battery settings menu.
- Check cable type:
- CAN requires shielded twisted pair
- RS485 requires A/B polarity correctness
- Test cables with multimeter for continuity.
- Verify termination resistors (120 Ω) are installed when required.
- Check BMS indicator lights or logs for communication status.
- Update inverter firmware and BMS firmware to latest versions.
Solutions
1. Correct protocol and ID setup
- Match inverter communication protocol with battery model.
- For multi-pack setups, ensure unique CAN addresses or proper daisy-chain.
2. Replace or re-crimp communication cables
Faulty cables are common — replace with genuine, shielded cables.
3. Check grounding and EMC interference
- Ground the cabinet.
- Keep communication cables away from AC lines.
4. Reset communication module
Perform a BMS soft reset or power-cycle inverter (safe sequence recommended).
5. Firmware alignment
Ensure compatibility between battery firmware and inverter firmware.
Prevention
- Use certified cables from manufacturer.
- Label all communication ports during installation.
- Avoid long cable runs (>10 m) unless shielded and grounded.
Quick FAQ
Q: Why does communication fail only when load is high?
A: High current may introduce electrical noise, especially if cables are not shielded. Improve cable shielding and separation.